dc.description.abstract |
The one-up one-down adaptive (staircase or up-down) procedure is often used to estimate the speech recognition
threshold (SRT) in speech-in-noise testing. This article provides a brief historical overview of the one-up one-down
procedure in psychophysics, discussing the groundbreaking early work that is still relevant to clinical audiology and
scientific research. Next, this article focuses on two aspects of the one-up one-down adaptive procedure: first, the
standard error of measurement (SEM) and, second, the fluctuations in the track [i.e., the standard deviation of the
signal-to-noise ratios of the stimuli within the track (SDtrack)]. Simulations of ideal and non-ideal listeners and experimental
data are used to determine and evaluate different relationships between the parameters slope of the speech
recognition function, SRT, SEM, and SDtrack. Hearing loss and non-ideal behavior (inattentiveness, fatigue, and giving
up when the task becomes too difficult) slightly increase the average value of SDtrack. SDtrack, however, poorly
discriminates between reliable and unreliable SRT estimates. |
en_US |
dc.description.department |
Speech-Language Pathology and Audiology |
en_US |
dc.description.librarian |
am2023 |
en_US |
dc.description.uri |
http://asa.scitation.org/journal/jas |
en_US |
dc.identifier.citation |
Smits, C. Festen, J.M., Swanepoel, D.W. et al. 2022, 'The one-up one-down adaptive (staircase) procedure in speech-in-noise testing : standard error of measurement and fluctuations in the track', Journal of the Acoustical Society of America, vol. 152, no. 4, pp. 2357-2368, doi : 10.1121/10.0014898. |
en_US |
dc.identifier.issn |
0001-4966 |
|
dc.identifier.other |
10.1121/10.0014898 |
|
dc.identifier.uri |
http://hdl.handle.net/2263/91996 |
|
dc.language.iso |
en |
en_US |
dc.publisher |
Acoustical Society of America |
en_US |
dc.rights |
© 2022 Author(s). licensed under a Creative Commons Attribution (CC BY) license. |
en_US |
dc.subject |
Speech-in-noise testing |
en_US |
dc.subject |
Psychophysics |
en_US |
dc.subject |
Speech recognition threshold (SRT) |
en_US |
dc.subject |
Speech-in-noise (SIN) |
en_US |
dc.subject |
Standard error of measurement (SEM) |
en_US |
dc.title |
The one-up one-down adaptive (staircase) procedure in speech-in-noise testing : standard error of measurement and fluctuations in the track |
en_US |
dc.type |
Article |
en_US |