Reliability of pulse oximetry at four different attachment sites in immobilized white rhinoceros (Ceratotherium simum)

Show simple item record

dc.contributor.author Mtetwa, Thembeka Kim
dc.contributor.author Snelling, Edward P.
dc.contributor.author Buss, Peter
dc.contributor.author Zeiler, Gareth Edward
dc.contributor.author Meyer, Leith Carl Rodney
dc.date.accessioned 2022-12-13T08:31:24Z
dc.date.issued 2022-11
dc.description.abstract OBJECTIVES : To determine the reliability of peripheral oxygen haemoglobin saturation (SpO2), measured by a Nonin PalmSAT 2500A pulse oximeter with 2000T transflectance probes at four attachment sites (third eyelid, cheek, rectum and tail), by comparing these measurements to arterial oxygen haemoglobin saturation (SaO2), measured by an AVOXimeter 4000 co-oximeter reference method in immobilized white rhinoceros (Ceratotherium simum). STUDY : Randomized crossover study. ANIMALS : A convenience sample of eight wild-caught male white rhinoceros. METHODS : White rhinoceros were immobilized with etorphine (0.0026 ± 0.0002 mg kg–1, mean ± standard deviation) intramuscularly, after which the pinna was aseptically prepared for arterial blood sample collection, and four pulse oximeters with transflectance probes were fixed securely to their attachment sites (third eyelid, cheek, rectum and tail). At 30 minutes following recumbency resulting from etorphine administration, the animals were given either butorphanol (0.026 ± 0.0001 mg kg–1) or an equivalent volume of saline intravenously. At 60 minutes following recumbency, insufflated oxygen (15 L minute–1 flow rate) was provided intranasally. In total, the SpO2 paired measurements from the third eyelid (n = 80), cheek (n = 67), rectum (n = 59) and tail (n = 76) were compared with near-simultaneous SaO2 measurements using Bland-Altman to assess bias (accuracy), precision, and the area root mean squares (ARMS) method. RESULTS : Compared with SaO2, SpO2 measurements from the third eyelid were reliable (i.e., accurate and precise) above an SaO2 range of 70% (bias = 1, precision = 3, ARMS = 3). However, SpO2 measurements from the cheek, rectum and tail were unreliable (i.e., inaccurate or imprecise). CONCLUSIONS AND CLINICAL RELEVANCE : A Nonin PalmSAT pulse oximeter with a transflectance probe inserted into the space between the third eyelid and the sclera provided reliable SpO2 measurements when SaO2 was > 70%, in immobilized white rhinoceros. en_US
dc.description.department Anatomy and Physiology en_US
dc.description.department Centre for Veterinary Wildlife Studies en_US
dc.description.department Companion Animal Clinical Studies en_US
dc.description.department Paraclinical Sciences en_US
dc.description.embargo 2023-10-31
dc.description.librarian hj2022 en_US
dc.description.sponsorship The National Research Foundation of South Africa, the South African Veterinary Association (Wildlife Group), the Wiederhold Foundation and the Department of Paraclinical Sciences, Faculty of Veterinary Science, University of Pretoria. en_US
dc.description.uri https://www.journals.elsevier.com/veterinary-anaesthesia-and-analgesia en_US
dc.identifier.citation Mtetwa, T.K., Snelling, E.P., Buss, P. et al. 2022, 'Reliability of pulse oximetry at four different attachment sites in immobilized white rhinoceros (Ceratotherium simum)', Veterinary Anaesthesia and Analgesia, vol. 49, no. 6, pp. 650-655, doi : 10.1016/j.vaa.2022.08.006. en_US
dc.identifier.issn 1467-2987 (print)
dc.identifier.issn 1467-2995 (online)
dc.identifier.other 10.1016/j.vaa.2022.08.006
dc.identifier.uri https://repository.up.ac.za/handle/2263/88752
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.rights © 2022 Published by Elsevier Ltd on behalf of Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Notice : this is the author’s version of a work that was accepted for publication in Veterinary Anaesthesia and Analgesia. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in Veterinary Anaesthesia and Analgesia, vol. 49, no. 6, pp. 650-655, 2022, doi : 10.1016/j.vaa.2022.08.006. en_US
dc.subject Chemical immobilization en_US
dc.subject Co-oximetry en_US
dc.subject Oxygen haemoglobin saturation en_US
dc.subject Pulse oximetry en_US
dc.subject White rhinoceros (Ceratotherium simum) en_US
dc.title Reliability of pulse oximetry at four different attachment sites in immobilized white rhinoceros (Ceratotherium simum) en_US
dc.type Postprint Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record