dc.description.abstract In order to ensure efficient, bulk-power transmission over a long distance, need of increasing transmission-level voltage is being thought for the past many years. As a result, Ultra High Voltage AC (UHVAC) Transmission has appeared as a feasible solution. Many countries like Italy, Japan, USA, USSR, Brazil, China, India are developing technology for UHVAC transmission systems. Operating at 1000 kV (and above voltage level) demands careful design of transmission structure, switchgear, and equipment design. This paper presents a review of several studies carried out to analyze the electro-magnetic environment in UHVAC lines. The electromagnetic environment (Field, Audible Noise, Corona Loss, Radio Interference) of 1200 kV, Wardha-Aurangabad single-circuit transmission line, India is also evaluated using FACE (Field and Corona Effect) software. The results of the study of static AC field and magnetic field of the line are found to be within prescribed limits suggested by International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. en_ZA
dc.description.department Electrical, Electronic and Computer Engineering en_ZA
dc.description.librarian hj2022 en_ZA
dc.description.uri http://www.journals.elsevier.com/ain-shams-engineering-journal en_ZA
dc.identifier.citation Bharti, S., Dubey, S.P., Nagwanshi, K.K. et al. 2022, 'Analysis of electromagnetic environment in 1200 kV single circuit UHVAC transmission line by using FACE software and semi-empirical formulae', Ain Shams Engineering Journal, vol. 13, no. 3, art. 101642, pp. 1-13. en_ZA
dc.identifier.issn 2090-4479
dc.identifier.other 10.1016/j.asej.2021.11.011
dc.identifier.uri http://hdl.handle.net/2263/83519
dc.language.iso en en_ZA
dc.publisher Elsevier en_ZA
dc.rights © 2021 The Authors. Published by Elsevier BV on behalf of Faculty of Engineering, Ain Shams University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). en_ZA
dc.subject UHVAC transmission line en_ZA
dc.subject Ultra high voltage AC (UHVAC) en_ZA
dc.subject Electromagnetic environment en_ZA
dc.subject Field and corona effect (FACE) software en_ZA
dc.subject Non-ionizing en_ZA
dc.subject Time varying electric fields en_ZA
dc.subject Time varying magnetic fields en_ZA
dc.subject Radiation en_ZA
dc.title Analysis of electromagnetic environment in 1200 kV single circuit UHVAC transmission line by using FACE software and semi-empirical formulae en_ZA