Allergic contact dermatitis from resin‑modified glass ionomers

Show simple item record

dc.contributor.author Buchanan, Glynn Dale
dc.contributor.author Tredoux, Sheree
dc.contributor.author Gamieldien, Mohamed Yasin
dc.date.accessioned 2021-03-24T06:34:09Z
dc.date.available 2021-03-24T06:34:09Z
dc.date.issued 2019-05
dc.description.abstract Monomers in a variety of dental materials may cause allergic contact dermatitis. While resin materials have been implicated in the onset of this condition, there is a paucity of evidence linking the condition to the resin‑modified glass ionomers (RMGIs). This report documents a rare case of a dentist who developed allergic contact dermatitis following exposure to a RMGI. Contact dermatitis occurred despite the use of latex gloves, which were worn during the procedure. Both the acute and chronic stages of the condition were clinically represented. Patch testing was conducted to confirm the diagnosis. A no‑touch technique and the routine use of nitrile gloves were subsequently adopted, which resulted in an overall decrease of the condition.Dentists, auxiliary personnel, and students should be aware of the possibility of sensitization to, and the development of allergic contact dermatitis not only from conventional resin materials, but also from the RMGIs. en_ZA
dc.description.department Maxillo-Facial and Oral Surgery en_ZA
dc.description.department Odontology en_ZA
dc.description.librarian am2021 en_ZA
dc.description.uri http://www.jcd.org.in en_ZA
dc.identifier.citation Buchanan, G.D., Tredoux, S. & Gamieldien, M.Y. Allergic contact dermatitis from resin-modified glass ionomers. Journal of Conservative Dentistry 2019; 22: 310-312. en_ZA
dc.identifier.issn 0972-0707 (print)
dc.identifier.issn 0974-5203 (online)
dc.identifier.other 10.4103/JCD.JCD_69_19
dc.identifier.uri http://hdl.handle.net/2263/79034
dc.language.iso en en_ZA
dc.publisher Medknow Publications en_ZA
dc.rights © 2019 Journal of Conservative Dentistry. This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution‑NonCommercial‑ShareAlike 4.0 License. en_ZA
dc.subject Allergic contact dermatitis en_ZA
dc.subject Gloves en_ZA
dc.subject Latex en_ZA
dc.subject Nitrile en_ZA
dc.subject Resin‑modified glass ionomer (RMGI) en_ZA
dc.title Allergic contact dermatitis from resin‑modified glass ionomers en_ZA
dc.type Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record