dc.contributor.author |
Hooijberg, Emma Henriette
|
|
dc.contributor.author |
Cray, Carolyn
|
|
dc.contributor.author |
Miller, Michele
|
|
dc.contributor.author |
Steenkamp, Gerhardus
|
|
dc.contributor.author |
Goddard, Amelia
|
|
dc.date.accessioned |
2020-10-20T09:31:17Z |
|
dc.date.issued |
2020-03 |
|
dc.description.abstract |
BACKGROUND : The bromocresol green (BCG) method has been reported to overestimate serum albumin concentration in several species due to non‐specific binding to globulins. As the white rhinoceros has high concentrations of serum globulins, significant differences in albumin measured by the BCG method, and the field method of agarose gel serum protein electrophoresis (SPE) are expected.
OBJECTIVES : We aimed to compare the BCG and SPE methods for albumin determination in the serum of white rhinoceroses. METHODS : SPE and BCG albumin were measured in 82 white rhinoceros serum samples. Results were compared using Bland‐Altman difference plots and Passing‐Bablok regression analysis. RESULTS : BCG albumin showed a significant mean constant positive bias of 7 g/L, or 36%, which was more than the total allowable error of 15% and was clinically significant. Methods were not comparable within the inherent imprecision of each method. CONCLUSIONS : The BCG method overestimated albumin concentrations in this species compared with agarose gel SPE, and method‐specific reference intervals should be used. |
en_ZA |
dc.description.department |
Companion Animal Clinical Studies |
en_ZA |
dc.description.embargo |
2021-01-10 |
|
dc.description.librarian |
hj2020 |
en_ZA |
dc.description.sponsorship |
The Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, South Africa and the Postgraduate research bursary from the Health and Welfare Sector Education and Training Authority, South Africa. |
en_ZA |
dc.description.uri |
http://wileyonlinelibrary.com/journal/vcp |
en_ZA |
dc.identifier.citation |
Hooijberg, E.H., Cray, C., Miller, M., Buss, P., Steenkamp, G., Goddard, A. Bias between two methods of
albumin measurement in the white rhinoceros, Ceratotherium
simum. Veterinary Clinical Pathology 2020;49:91–94. https://doi.org/10.1111/vcp.12820. |
en_ZA |
dc.identifier.issn |
0275-6382 (print) |
|
dc.identifier.issn |
1939-165X (online) |
|
dc.identifier.other |
10.1111/vcp.12820 |
|
dc.identifier.uri |
http://hdl.handle.net/2263/76551 |
|
dc.language.iso |
en |
en_ZA |
dc.publisher |
Wiley |
en_ZA |
dc.rights |
© 2020 American Society for Veterinary Clinical Pathology. This is the pre-peer reviewed version of the following article : Bias between two methods of
albumin measurement in the white rhinoceros, Ceratotherium simum. Veterinary Clinical Pathology 2020;49:91–94. https://doi.org/10.1111/vcp.12820. The definite version is available at : http://wileyonlinelibrary.com/journal/vcp. |
en_ZA |
dc.subject |
Bromocresol green (BCG) |
en_ZA |
dc.subject |
White rhinoceros (Ceratotherium simum) |
en_ZA |
dc.subject |
Method comparison |
en_ZA |
dc.subject |
Serum protein electrophoresis (SPE) |
en_ZA |
dc.title |
Bias between two methods of albumin measurement in the white rhinoceros, Ceratotherium simum |
en_ZA |
dc.type |
Postprint Article |
en_ZA |