Bias between two methods of albumin measurement in the white rhinoceros, Ceratotherium simum

Show simple item record

dc.contributor.author Hooijberg, Emma Henriette
dc.contributor.author Cray, Carolyn
dc.contributor.author Miller, Michele
dc.contributor.author Steenkamp, Gerhardus
dc.contributor.author Goddard, Amelia
dc.date.accessioned 2020-10-20T09:31:17Z
dc.date.issued 2020-03
dc.description.abstract BACKGROUND : The bromocresol green (BCG) method has been reported to overestimate serum albumin concentration in several species due to non‐specific binding to globulins. As the white rhinoceros has high concentrations of serum globulins, significant differences in albumin measured by the BCG method, and the field method of agarose gel serum protein electrophoresis (SPE) are expected. OBJECTIVES : We aimed to compare the BCG and SPE methods for albumin determination in the serum of white rhinoceroses. METHODS : SPE and BCG albumin were measured in 82 white rhinoceros serum samples. Results were compared using Bland‐Altman difference plots and Passing‐Bablok regression analysis. RESULTS : BCG albumin showed a significant mean constant positive bias of 7 g/L, or 36%, which was more than the total allowable error of 15% and was clinically significant. Methods were not comparable within the inherent imprecision of each method. CONCLUSIONS : The BCG method overestimated albumin concentrations in this species compared with agarose gel SPE, and method‐specific reference intervals should be used. en_ZA
dc.description.department Companion Animal Clinical Studies en_ZA
dc.description.embargo 2021-01-10
dc.description.librarian hj2020 en_ZA
dc.description.sponsorship The Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, South Africa and the Postgraduate research bursary from the Health and Welfare Sector Education and Training Authority, South Africa. en_ZA
dc.description.uri http://wileyonlinelibrary.com/journal/vcp en_ZA
dc.identifier.citation Hooijberg, E.H., Cray, C., Miller, M., Buss, P., Steenkamp, G., Goddard, A. Bias between two methods of albumin measurement in the white rhinoceros, Ceratotherium simum. Veterinary Clinical Pathology 2020;49:91–94. https://doi.org/10.1111/vcp.12820. en_ZA
dc.identifier.issn 0275-6382 (print)
dc.identifier.issn 1939-165X (online)
dc.identifier.other 10.1111/vcp.12820
dc.identifier.uri http://hdl.handle.net/2263/76551
dc.language.iso en en_ZA
dc.publisher Wiley en_ZA
dc.rights © 2020 American Society for Veterinary Clinical Pathology. This is the pre-peer reviewed version of the following article : Bias between two methods of albumin measurement in the white rhinoceros, Ceratotherium simum. Veterinary Clinical Pathology 2020;49:91–94. https://doi.org/10.1111/vcp.12820. The definite version is available at : http://wileyonlinelibrary.com/journal/vcp. en_ZA
dc.subject Bromocresol green (BCG) en_ZA
dc.subject White rhinoceros (Ceratotherium simum) en_ZA
dc.subject Method comparison en_ZA
dc.subject Serum protein electrophoresis (SPE) en_ZA
dc.title Bias between two methods of albumin measurement in the white rhinoceros, Ceratotherium simum en_ZA
dc.type Postprint Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record