Automatic landmarking as a convenient prerequisite for geometric morphometrics : validation on cone beam computed tomography (CBCT)- based shape analysis of the nasal complex

Show simple item record

dc.contributor.author Ridel, Alison Fany
dc.contributor.author Demeter, F.
dc.contributor.author Galland, M.
dc.contributor.author L'Abbe, Ericka Noelle
dc.contributor.author Vandermeulen, Dirk
dc.contributor.author Oettle, Anna Catherina
dc.date.accessioned 2020-04-30T09:38:36Z
dc.date.available 2020-04-30T09:38:36Z
dc.date.issued 2020-01
dc.description.abstract Manual landmarking is used in several manual and semi-automated prediction guidelines for approximation of the nose. The manual placement of landmarks may, however, render the analysis less repeatable due to observer subjectivity and, consequently, have an impact on the accuracy of the human facial approximation. In order to address this subjectivity and thereby improve facial approximations, we are developing an automated three-dimensional (3D) method based on an automatic dense landmarking procedure using non-rigid surface registration. The aim of this study was to validate the automatic landmarking method by comparing the intra-observer errors (INTRA-OE) and inter-observer errors (INTER-OE) between automatic and manual landmarking. Cone beam computed tomography (CBCT) scans of adult South Africans were selected from the Oral and Dental Hospital, University of Pretoria, South Africa. In this study, the validation of the automatic landmarking was performed on 20 3D surfaces. INTRA-OE and INTER-OE were analyzed by registering 41 craniometric landmarks from 10 hard-tissue surfaces and 21 capulometric landmarks from 10 soft-tissue surfaces of the same individuals. Absolute precision of the landmark positioning (both on the samples as well as the template) was assessed by calculating the measurement error (ME) for each landmark over different observers. Systematic error (bias) and relative random error (precision) was further quantified through repeated measures ANOVA (ANOVA-RM). The analysis showed that the random component of the ME in landmark positioning between the automatic observations were on average on par with the manual observations, except for the soft-tissue landmarks where automatic landmarking showed lower ME compared to manual landmarking. No bias was observed within the craniometric landmarking methods, but some bias was observed for capulometric landmarking. In conclusion, this research provides a first validation of the precision and accuracy of the automatic placement of landmarks on 3D hard- and soft-tissue surfaces and demonstrates its utilization as a convenient prerequisite for geometric morphometrics based shape analysis of the nasal complex. en_ZA
dc.description.department Anatomy en_ZA
dc.description.embargo 2021-01-01
dc.description.librarian am2020 en_ZA
dc.description.sponsorship The AESOP + consortia, UMR 5288 CNRS- Université Paul- Sabatier, 37, allées Jules-Guesde, 31000 Toulouse, and the Evolutionary Studies Institute and School of Geosciences, University of the Witwatersrand, Johannesburg, South Africa. en_ZA
dc.description.uri http://www.elsevier.com/locate/forsciint en_ZA
dc.identifier.citation Ridel, A.F., Demeter, F., Galland, M. et al. 2020, 'Automatic landmarking as a convenient prerequisite for geometric morphometrics : validation on cone beam computed tomography (CBCT)- based shape analysis of the nasal complex', Forensic Science International, vol. 306, art. 110095, pp. 1-10. en_ZA
dc.identifier.issn 0379-0738 (print)
dc.identifier.issn 1872-6283 (online)
dc.identifier.other 10.1016/j.forsciint.2019.110095
dc.identifier.uri http://hdl.handle.net/2263/74436
dc.language.iso en en_ZA
dc.publisher Elsevier en_ZA
dc.rights © 2019 Elsevier B.V. All rights reserved. Notice : this is the author’s version of a work that was accepted for publication in Forensic Science International. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in Forensic Science International, vol. 306, art. 110095, pp. 1-10, 2019. doi : 10.1016/j.forsciint.2019.110095. en_ZA
dc.subject Non-rigid surface registration en_ZA
dc.subject Automatic craniometric landmarking en_ZA
dc.subject Automatic capulometric landmarking en_ZA
dc.subject Manual landmarking en_ZA
dc.subject Intra- and inter- observer errors en_ZA
dc.subject.other Health sciences articles SDG-03
dc.subject.other SDG-03: Good health and well-being
dc.title Automatic landmarking as a convenient prerequisite for geometric morphometrics : validation on cone beam computed tomography (CBCT)- based shape analysis of the nasal complex en_ZA
dc.type Postprint Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record