Clinical evaluation of the loop-design fibre-reinforced composite and the band-and-loop space maintainers

Show simple item record

dc.contributor.author Potgieter, Nicoline
dc.contributor.author Brandt, Paul Dieter
dc.contributor.author Mohamed, Nadia
dc.date.accessioned 2019-07-05T07:52:07Z
dc.date.available 2019-07-05T07:52:07Z
dc.date.issued 2018-08
dc.description.abstract PURPOSE : The fibre-reinforced composite space maintainer (FRCSM) has been suggested as an alternative to the band-and-loop space maintainer (BLSM). The aim of this in-vivo study was to evaluate the clinical performance and the reasons for failure of the two types of fixed space maintainers over a six-month period. METHODS : Twenty patients, ranging from 4-9 years old, were selected for this study. They were randomly divided into two groups (n=10) according to the type of space maintainer that was placed. The patients were recalled on a monthly basis for clinical evaluation over a period of six months. The two-sample t-test and the non-parametric Wilcoxon rank sum test were used for statistical analysis. RESULTS : Both groups of space maintainers had a 50% failure rate. The main reason for BLSM failure was bending of the wire with impingement on the soft tissue. The FRCSM failed due to debonding and fracture of the fibre loop. There was no statistically significant difference between the failure rates (P=0.53). CONCLUSION : The clinical performances of both space maintainers were disappointing. Only 50% of fixed space maintainers were still clinically acceptable according to the strict evaluation criteria used. Further research is recommended on the loop-design FRCSM. en_ZA
dc.description.department Odontology en_ZA
dc.description.librarian am2019 en_ZA
dc.description.uri https://www.sada.co.za/the-sadj en_ZA
dc.identifier.citation Potgieter, N., Brandt, P.D. & Mohamed, N. 2018, 'Clinical evaluation of the loop-design fibre-reinforced composite and the band-and-loop space maintainers', South African Dental Journal, vol. 73, no. 7, pp. 436-441. en_ZA
dc.identifier.issn 1029-4864 (print)
dc.identifier.issn 2519-0105 (online)
dc.identifier.other 10.17159/2519-0105/2018/v73no7a1
dc.identifier.uri http://hdl.handle.net/2263/70382
dc.language.iso en en_ZA
dc.publisher South African Dental Association en_ZA
dc.rights © 2019 E-Doc cc en_ZA
dc.subject Space maintenance en_ZA
dc.subject Fibre-reinforced composite space maintainer (FRCSM) en_ZA
dc.subject Band-and-loop space maintainer (BLSM) en_ZA
dc.title Clinical evaluation of the loop-design fibre-reinforced composite and the band-and-loop space maintainers en_ZA
dc.type Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record