dc.contributor.author |
Todorovic, Vladimir S.
|
|
dc.contributor.author |
Postma, Thomas Corne
|
|
dc.contributor.author |
Van Zyl, Andre W.
|
|
dc.date.accessioned |
2018-02-06T08:16:28Z |
|
dc.date.issued |
2018-04 |
|
dc.description.abstract |
The anterior loop of the inferior alveolar nerve (IAN) is an important landmark in the anterior mandible that must be considered during the placement of dental implants. We measured the length and prevalence of loops of the IAN in 188 consecutive, dentate patients using reformatted computed tomography (CT). A total of 158/188 (84%) had at least one anterior loop; 111/188 (59%) had bilateral loops. The mean (SD) length of the loops in the third quadrant was 1.4 (0.7) mm; 95% CI 1.3 to 1.6; (range 0.3 – 4.0 mm). The mean (SD) length of the loops in the fourth quadrant was 1.5 (0.9) mm; 95% CI 1.4 to 1.6; range 0.3 – 5.5 mm. In total 42/188 (22%) had loops that were longer than 2 mm in quadrants three and four. CT images that have been reformatted with specialised software may be useful to identify loops in the IAN, particularly when recent cone-beam CT images are not freely available. The prevalence of these loops is high while their length varies, which makes meticulous assessment necessary before the placement of implants. |
en_ZA |
dc.description.department |
Dental Management Sciences |
en_ZA |
dc.description.department |
Periodontics and Oral Medicine |
en_ZA |
dc.description.embargo |
2019-04-01 |
|
dc.description.librarian |
hj2018 |
en_ZA |
dc.description.uri |
http://bjoms.com |
en_ZA |
dc.description.uri |
http://www.journals.elsevier.com/british-journal-of-oral-and-maxillofacial-surgery |
en_ZA |
dc.identifier.citation |
Todorovic, V.S., Postma, T.C. & Van Zyl, A.W. Assessment of the anterior loop of the inferior alveolar nerve using reformatted computed tomography: a retrospective study. British Journal of Oral and Maxillofacial Surgery (2018) 56(3): 186-191, https://doi.org/10.1016/j.bjoms.2018.01.007. |
en_ZA |
dc.identifier.issn |
0266-4356 (print) |
|
dc.identifier.issn |
1532-1940 (online) |
|
dc.identifier.other |
10.1016/j.bjoms.2018.01.007 |
|
dc.identifier.uri |
http://hdl.handle.net/2263/63865 |
|
dc.language.iso |
en |
en_ZA |
dc.publisher |
Elsevier |
en_ZA |
dc.rights |
© 2018 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved. Notice : this is the author’s version of a work that was accepted for publication in British Journal of Oral and Maxillofacial Surgery. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. A definitive version was subsequently published in British Journal of Oral and Maxillofacial Surgery, vol. 56, no. 3, pp. 186-191. 2018. doi : 10.1016/j.bjoms.2018.01.007. |
en_ZA |
dc.subject |
Inferior alveolar nerve (IAN) |
en_ZA |
dc.subject |
Computed tomography (CT) |
en_ZA |
dc.subject |
Dental implant surgery |
en_ZA |
dc.subject |
Multi-slice computed tomography |
en_ZA |
dc.subject |
Anterior loop |
en_ZA |
dc.subject |
Mandibular nerve |
en_ZA |
dc.subject.other |
Health sciences articles SDG-03 |
|
dc.subject.other |
SDG-03: Good health and well-being |
|
dc.subject.other |
Health sciences articles SDG-09 |
|
dc.subject.other |
SDG-09: Industry, innovation and infrastructure |
|
dc.title |
Assessment of the anterior loop of the inferior alveolar nerve using reformatted computed tomography : a retrospective study |
en_ZA |
dc.type |
Postprint Article |
en_ZA |