Numerical and experimental analysis of the thermal behavior of dry-type transformer supplying nonlinear loads

Show simple item record

dc.contributor.author Mafra, R.G. en
dc.contributor.author Anselmo, B.C.S. en
dc.contributor.author Belchior, F.N. en
dc.contributor.author Lima e Silva, S.M.M. en
dc.date.accessioned 2017-09-19T12:48:23Z
dc.date.available 2017-09-19T12:48:23Z
dc.date.issued 2017 en
dc.description Papers presented at the 13th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Portoroz, Slovenia on 17-19 July 2017 . en
dc.description.abstract Thermal behavior of the transformers is affected by distorted loads caused by the influence of electronic equipment in the electric current. The aim of this work is to analyze the thermal behavior of a 5 kVA dry-type transformer working with linear and non-linear loads. Thermocouples and PT100 were used to measure the temperatures inside the cores. In addition, fans were used inside the transformers to analyze the influence of forced convection in the temperatures. Empirical correlations from literature were used to determine the average heat transfer coefficient used in the numerical analysis and to validate the results obtained in this work. The emissivity of the core surface was measured with a thermal camera. COMSOL software was used for the numerical simulation of the heating of transformers under the effect of certain loading and cooling conditions. Comparisons between experimental and numerical temperatures were carried out to validate the methodology. Hot Spots temperatures and their locations were also possible to be estimated with this methodology. The Hot Spots temperature in the core reached 20 °C above the transformer insulation limit. These temperatures and locations will serve in the future to optimize cooling projects of shell-type transformers. en
dc.description.sponsorship International centre for heat and mass transfer. en
dc.description.sponsorship American society of thermal and fluids engineers. en
dc.format.extent 6 pages en
dc.format.medium PDF en
dc.identifier.uri http://hdl.handle.net/2263/62343
dc.language.iso en en
dc.publisher HEFAT en
dc.rights University of Pretoria en
dc.subject Dry-type transformer en
dc.subject Nonlinear loads en
dc.subject Thermal behaviour en
dc.title Numerical and experimental analysis of the thermal behavior of dry-type transformer supplying nonlinear loads en
dc.type Presentation en