Thermal comfort levels in a conditioned environment with displacement ventilation and radiant cooling floor calculated using computational fluid dynamics

Show simple item record

dc.contributor.author Pena-Suarez, J.M. en
dc.contributor.author Ortega-Casanova, J. en
dc.date.accessioned 2017-08-28T07:08:11Z
dc.date.available 2017-08-28T07:08:11Z
dc.date.issued 2016 en
dc.description Papers presented to the 12th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Costa de Sol, Spain on 11-13 July 2016. en
dc.description.abstract In a society in continuous development, the requirements for thermal comfort and indoor air quality are increasing. However, these should be achieved by rational energy consumption. With this in mind, the combined use of displacement ventilation (DV) and radiant cooling floor (RCF) is an innovative concept that has become popular as a cooling system in high-rise public enclosures. To provide a high thermal comfort, the effects of buoyancy, supplied air temperature, air discharge angle and surface floor temperature should be treated with special care. Therefore, this paper presents a sensitivity analysis considering these critical parameters in different numerical simulations. The results of the simulations are used to calculate the thermal comfort index, according to ISO 7730 standard, in high ceiling enclosures using a DV + RCF system. The general thermal sensation has been predicted using the PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) indices. The local thermal discomfort has been evaluated by radiant temperature asymmetry, draught, vertical air temperature differences and floor surface temperatures. According to these indices, the classification of Category A is reached using DV + RCF system, exception of the radiant temperature asymmetry index. That fact will be discussed in detail, analyzed the suitability of the calculation indicates in ISO 7730 for systems involved in radiating surfaces. en
dc.format.extent 6 pages en
dc.format.medium PDF en
dc.identifier.uri http://hdl.handle.net/2263/61983
dc.language.iso en en
dc.publisher HEFAT en
dc.rights University of Pretoria en
dc.subject Radiant cooling floor en
dc.subject Thermal comfort levels en
dc.subject Computation fluid en
dc.title Thermal comfort levels in a conditioned environment with displacement ventilation and radiant cooling floor calculated using computational fluid dynamics en
dc.type Presentation en