Evaluation of a continuous miner half-curtain dust control system in a South African underground coal mine

Show simple item record

dc.contributor.author Belle, Bharath K.
dc.contributor.author Du Plessis, J.J.L.
dc.date.accessioned 2017-03-24T06:54:48Z
dc.date.available 2017-03-24T06:54:48Z
dc.date.issued 1999-01
dc.description.abstract The project was planned in two phases. The first phase involved laboratory tests on a continuous miner model for different ventilation and spray systems at the newly built ventilation simulation tunnel at the Klopperbos research centre. In the second phase of the project, tests were carried out underground based on the findings and recommendations from the simulated tests. This paper focuses on the results and findings for the half-curtain system which have been encouraging. The average dust concentration for the sampling period at the operator’s position for the half-curtain system was 3.20 mg/m3. On the other hand, the equivalent average dust concentration (TWA-CONC) for the half-curtain system for a 8-h period was 2.04 mg/m3. The outcome of this project has shown that the regulatory dust level of <5 mg/m3 can be achieved through close collaboration with all the interested parties. en_ZA
dc.description.department Mining Engineering en_ZA
dc.description.librarian am2017 en_ZA
dc.description.uri http://www.mvssa.co.za en_ZA
dc.identifier.citation Belle, BK & Du Plessis, JJL 1999, 'Evaluation of a continuous miner half-curtain dust control system in a South African underground coal mine', Journal of the Mine Ventilation Society of South Africa, pp. 4-9. en_ZA
dc.identifier.issn 0368-3206
dc.identifier.uri http://hdl.handle.net/2263/59514
dc.language.iso en en_ZA
dc.publisher Mine Ventilation Society of South Africa en_ZA
dc.rights Mine Ventilation Society of South Africa en_ZA
dc.subject Laboratory tests en_ZA
dc.subject Klopperbos research centre en_ZA
dc.subject Dust control system en_ZA
dc.subject South African underground coal mine en_ZA
dc.subject Continuous miner model en_ZA
dc.subject Ventilation system en_ZA
dc.subject Spray system en_ZA
dc.title Evaluation of a continuous miner half-curtain dust control system in a South African underground coal mine en_ZA
dc.type Article en_ZA