Biomechanical comparison between pins - polymethylmethacrylate to the “String of Pearls” interlocking plate system (SOP) to stabilize canine lumbosacral fracture-luxation

Show simple item record

dc.contributor.advisor Coetzee, Gert Louis
dc.contributor.author Nel, Johannes J.
dc.contributor.author Kat, Cor-Jacques
dc.contributor.author Coetzee, Gert Louis
dc.date.accessioned 2016-08-02T08:14:58Z
dc.date.available 2016-08-02T08:14:58Z
dc.date.issued 2015-08-20
dc.description Poster presented at the University of Pretoria, Faculty of Veterinary Science Faculty Day, August 20, 2015, Pretoria, South Africa. en_ZA
dc.description Created in CoralDRAW X5. PDF size: 5.83 MB. en_ZA
dc.description.abstract Biomechanical comparison of two internal spinal fixation techniques, applied to a surgically simulated complete spinal injury at L7-S1 was conducted. The study objective was to compare the stability provided by the two fixation techniques to the fracture-luxation. en_ZA
dc.description.librarian ab2016 en_ZA
dc.format.extent 1 poster : color photos en_ZA
dc.format.medium PDF file en_ZA
dc.identifier.uri http://hdl.handle.net/2263/56175
dc.language.iso en en_ZA
dc.publisher Pretoria : University of Pretoria. Faculty of Veterinary Science, Dept. Companion Animal Clinical Studies en_ZA
dc.relation.ispartofseries Veterinary Science Faculty Day posters 2015 en_ZA
dc.relation.requires Abode Acrobat reader en_ZA
dc.rights ©University of Pretoria. Faculty of Veterinary Science (Original and digital). Provided for educational purposes only. It may not be downloaded, reproduced, or distributed in any format without written permission of the original copyright holder. Any attempt to circumvent the access controls placed on this file is a violation of copyright laws and is subject to criminal prosecution. Please contact the collection administrator for copyright issues. en_ZA
dc.subject Lumbosacral joint en_ZA
dc.subject Spinal fixation en_ZA
dc.subject Biomechanical comparison en_ZA
dc.subject Implant stability en_ZA
dc.subject.lcsh Veterinary medicine -- Posters en_ZA
dc.subject.lcsh Veterinary orthopedics en_ZA
dc.subject.lcsh Internal fixation in fractures en_ZA
dc.subject.lcsh Dogs -- Fractures en_ZA
dc.title Biomechanical comparison between pins - polymethylmethacrylate to the “String of Pearls” interlocking plate system (SOP) to stabilize canine lumbosacral fracture-luxation en_ZA
dc.type Presentation en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record