Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

Show simple item record

dc.contributor.author Hudyana, Hendrah
dc.contributor.author Maes, Alex
dc.contributor.author Vandenberghe, Thierry
dc.contributor.author Fidlers, Luc
dc.contributor.author Sathekge, Mike Machaba
dc.contributor.author Nicolai, Daniel
dc.contributor.author Van de Wiele, Christophe
dc.date.accessioned 2015-11-26T08:24:41Z
dc.date.issued 2016-02
dc.description.abstract BACKGROUND : The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard Methods A total of 48 patients (median age 49 years, range 21–81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/ CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CTscanswere determined to be false negatives if surgery was still required and loosening of material was found. RESULTS : The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12– 192 months). Median follow-up was 18 months (range 6– 57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients.Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac osteodegeneration in 7 patients and 1 patient, respectively). Overall sensitivity and specificity for the detection of loosening were 100 % and 89.7 %, respectively. The positive and negative predictive values were 69 % and 100 %, respectively. CONCLUSIONS : This retrospective analysis suggests that bone SPECT/CT bone is a highly sensitive and specific tool for the exclusion of screw loosening in patients who present with recurrent low back pain after having undergone lumbar arthrodesis. In addition, it can identify other potential causes of recurrent low back pain in this patient population. en_ZA
dc.description.embargo 2017-02-20
dc.description.librarian hb2015 en_ZA
dc.description.uri http://link.springer.com/journal/259 en_ZA
dc.identifier.citation Hudyana, H, Maes, A, Vandenberghe, T, Fidlers, L, Sathekge, M, Nicolai, D & Van de Wiele, C 2016, 'Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws', European Journal of Nuclear Medicine and Molecular Imaging, vol. 43, no. 2, pp 349-354. en_ZA
dc.identifier.issn 0340-6997 (print)
dc.identifier.issn 1432-105X (online)
dc.identifier.other 10.1007/s00259-015-3158-7
dc.identifier.uri http://hdl.handle.net/2263/50928
dc.language.iso en en_ZA
dc.publisher Springer en_ZA
dc.rights © Springer-Verlag 2015. The original publication is available at : http://link.springer.comjournal/259. en_ZA
dc.subject Bone SPECT-CT en_ZA
dc.subject Lumbar fusion en_ZA
dc.subject Pedicle screws en_ZA
dc.subject Loosening en_ZA
dc.subject Single photon emission computed tomography (SPECT) en_ZA
dc.subject Computed tomography (CT) en_ZA
dc.title Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws en_ZA
dc.type Postprint Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record