A cheap and simple passive sampler using silicone rubber for the analysis of surface water by gas chromatography–time of flight mass spectrometry

Show simple item record

dc.contributor.author Naude, Yvette
dc.contributor.author Gorst-Allman, Peter
dc.contributor.author Rohwer, Egmont Richard
dc.date.accessioned 2015-08-19T09:23:31Z
dc.date.available 2015-08-19T09:23:31Z
dc.date.issued 2015
dc.description This paper was originally presented at the 2014 Water Institute of Southern Africa (WISA) Biennial Conference, Mbombela, 25–29 May 2014. en_ZA
dc.description.abstract Water pollution events may arise rapidly, requiring a methodology that is easy to implement, fast to deploy, and sufficiently sensitive to detect the trace presence of hazardous contaminants. A cheap and easy to use silicone rubber (polydimethylsiloxane (PDMS)) miniature passive sampler is described. In order to test the methodology, pollutants were concentrated, in situ, from surface water in and around Pretoria, South Africa. The versatile sampler allowed for conventional and enhanced sensitivity, solvent-free analysis by comprehensive gas chromatography – time of flight mass spectrometry (GCxGC-TOFMS) and high resolution TOFMS (GC-HRT). Contaminants detected in surface water include caffeine, personal care products, pharmaceuticals, pesticides and polycyclic aromatic hydrocarbons. en_ZA
dc.description.librarian am2015 en_ZA
dc.description.sponsorship National Research Foundation (NRF) en_ZA
dc.description.uri http://www.wrc.org.za en_ZA
dc.identifier.citation Naude, Y, Gorst-Allman, P & Rohwer, E 2015, 'A cheap and simple passive sampler using silicone rubber for the analysis of surface water by gas chromatography–time of flight mass spectrometry', Water SA, vol. 41, no. 2, pp. 182-188. en_ZA
dc.identifier.issn 0378-4738 (print)
dc.identifier.issn 1816-7950 (online)
dc.identifier.other 10.4314/wsa.v41i2.02
dc.identifier.uri http://hdl.handle.net/2263/49397
dc.language.iso en en_ZA
dc.publisher Water Research Commission en_ZA
dc.rights Water Research Commission en_ZA
dc.subject Passive sampler en_ZA
dc.subject Silicone rubber (PDMS) tubing en_ZA
dc.subject GCxGC-TOFMS en_ZA
dc.subject GC-HRT en_ZA
dc.subject Surface water quality en_ZA
dc.title A cheap and simple passive sampler using silicone rubber for the analysis of surface water by gas chromatography–time of flight mass spectrometry en_ZA
dc.type Article en_ZA


Files in this item

This item appears in the following Collection(s)

Show simple item record