Analysis and Optimisation of a Receiver Tube for Direct Steam Generation in a Solar Parabolic Trough Collector

Show simple item record

dc.contributor.advisor Bello-Ochende, Tunde en
dc.contributor.coadvisor Meyer, Josua P.
dc.contributor.postgraduate Nolte, Henriette C. en
dc.date.accessioned 2015-07-02T11:06:11Z
dc.date.available 2015-07-02T11:06:11Z
dc.date.created 2015/04/23 en
dc.date.issued 2014 en
dc.description Dissertation (MEng)--University of Pretoria, 2014. en
dc.description.abstract This study focused on a numerical second law analysis and optimisation of a receiver tube op- erating in a parabolic trough solar collector for small-scale application. The receiver functioned in a Rankine cycle. The focus was on entropy generation minimisation in the receiver due to the high quality exergy losses in this component. Water functioned as the working uid and was heated from ambient conditions (liquid) to a superheated state (vapour), consequently, the receiver tube was subject to both single phase as well as two-phase ow. Entropy generation in the receiver tube was mainly due to nite temperature di erences as well as uid friction. The contribution of each of these components was investigated. Geometrical as well as operating conditions were investigated to obtain good guidelines for receiver tube and plant design. An operating pressure in the range of 1 MPa (Tsat = 180 C) to 10 MPa (Tsat = 311 C) was considered. Furthermore a mass ow range of 0:15 kg=s to 0:4 kg=s was investigated. Results showed that beyond a diameter of 20 mm, the main contributor to the entropy generation was the nite temperature di erences for most conditions. Generally, operating pressures below 3 MPa showed bad performance since the uid friction component was too large for small operating pressures. This phenomenon was due to long two-phase lengths and high pressure drops in this region. The nite temperature di erence component increased linearly when the tube diameter was increased (due to the increase in exposed area) if the focused heat ux was kept constant. However, the uid friction component increased quadratically when the diameter was reduced. In general when the concentration ratio was increased, the entropy generation was decreased. This was due to more focused heat on each section of the receiver pipe and, in general, resulted in shorter receiver lengths. Unfortunately, there is a limit to the highest concentration ratio that can be achieved and in this study, it was assumed to be 45 for two-dimensional trough technology. A Simulated Annealing (SA) optimisation algorithm was implemented to obtain certain optimum parameters. The optimisation showed that increasing the diameter could result in a decrease in entropy generation, provided that the concentration ratio is kept constant. However, beyond a certain point gains in minimising the entropy generation became negligible. Optimal operating pressure would generally increase if the mass ow rate was increased. Finally, it was seen that the highest operating pressure under consideration (10 MPa) showed the best performance when considering the minimisation of entropy in conjunction with the maximisation of the thermodynamic work output. en
dc.description.availability Unrestricted en
dc.description.degree MEng en
dc.description.department Mechanical and Aeronautical Engineering en
dc.description.librarian tm2015 en
dc.identifier.citation Nolte, HC 2014, Analysis and Optimisation of a Receiver Tube for Direct Steam Generation in a Solar Parabolic Trough Collector, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/45965> en
dc.identifier.other A2015 en
dc.identifier.uri http://hdl.handle.net/2263/45965
dc.language.iso en en
dc.publisher University of Pretoria en_ZA
dc.rights © 2015 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en
dc.subject UCTD en
dc.subject Solar Thermal Energy
dc.subject Direct Steam Generation (DSG)
dc.subject Receiver Tube
dc.subject Two-Phase Flow
dc.subject Second Law Analysis
dc.subject Entropy Generation
dc.title Analysis and Optimisation of a Receiver Tube for Direct Steam Generation in a Solar Parabolic Trough Collector en