Experimental investigation of heat transfer during LOCA with failure of emergency cooling system

Show simple item record

dc.contributor.author Nandan, Gopal
dc.contributor.author Lele, H.G.
dc.contributor.author Sahoo, P.K.
dc.contributor.author Chatterjee, B.
dc.contributor.author Kumar, Ravi
dc.contributor.author Mukhopadhyay, D.
dc.date.accessioned 2015-06-11T10:53:54Z
dc.date.available 2015-06-11T10:53:54Z
dc.date.issued 2007
dc.description.abstract Paper presented at the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July, 2007. en_ZA
dc.description.abstract The pressure tubes (PT) in the Indian Pressurized Heavy Water Reactor (PHWR) are kept concentrically inside horizontal calandria tube (CT), which is submerged in a moderator pool. During postulated loss-of-coolant accident (LOCA) without emergency core cooling system, the temperature of PT could rise significantly. At elevated temperature, the weight of the PT with the weight of fuel pins could cause it to sag. Before sagging heat transfer from the PT to CT is mainly by convection. Once the PT sags and touches the CT, heat transfer mode changes to conduction. Direct contact between the PT and CT increases heat transfer and checks the temperature rise of the PT and limit the fuel heatup and subsequent degradation of the reactor core. An experimental set-up is designed and fabricated at Indian Institute of Technology Roorkee (IITR) to simulate the LOCA in the Indian PHWR. From the experimental investigation, it is found that the contact between the PT and CT occurred at around 300 seconds after the initiation of the simulation with corresponding temperature of the PT at around 680°C. The experiment was continued after the contact between the PT and CT and it is found that the temperature rise of the PT was within 800°C. This work demonstrates the inherent safety feature of Pressurised Heavy Water Reactor. en_ZA
dc.description.librarian cs2014 en_ZA
dc.format.extent 5 pages en_ZA
dc.format.medium PDF en_ZA
dc.identifier.citation Nandan, G, Lele, HG, Sahoo, PK, Chatterjee, B, Kumar, R & Mukhopadhyay, D 2007, 'Experimental investigation of heat transfer during LOCA with failure of emergency cooling system', Paper presented to the 5th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, South Africa, 1-4 July 2007. en_ZA
dc.identifier.isbn 9781868546435
dc.identifier.uri http://hdl.handle.net/2263/45468
dc.language.iso en en_ZA
dc.publisher International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics en_ZA
dc.relation.ispartof HEFAT 2007
dc.rights University of Pretoria en_ZA
dc.rights.uri University of Pretoria en_US
dc.subject Pressure tubes en_ZA
dc.subject Indian pressurized heavy water reactor en_ZA
dc.subject Calandria tube en_ZA
dc.subject Loss-of-coolant accident en_ZA
dc.subject Heat transfer en_ZA
dc.subject Indian Institute of Technology Roorkee en_ZA
dc.subject Pressurised Heavy Water Reactor en_ZA
dc.title Experimental investigation of heat transfer during LOCA with failure of emergency cooling system en_ZA