dc.contributor.author |
Akella, Suresh
|
|
dc.contributor.author |
Reddy, Kishen Kumar T.
|
|
dc.date.accessioned |
2015-04-28T07:02:30Z |
|
dc.date.available |
2015-04-28T07:02:30Z |
|
dc.date.issued |
2010 |
|
dc.description.abstract |
Paper presented at the 7th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Turkey, 19-21 July, 2010. |
en_ZA |
dc.description.abstract |
Energy is becoming dearer. Saving power of domestic appliances is not only for cost benefits but a social obligation and sustaining environment. Hermetic compressor being the heart of an air conditioner, in it's function and also in the power consumption, it is continuously redesigned for increased efficiency, capacity and noise. Two terms get optimised in improving efficiency the capacity delivered and the power consumed. Noise is independently evaluated.
This study helped in identifying root causes of losses and providing corrections to improve the
efficiency of fixed and variable frequency compressors to our customer's satisfaction. |
|
dc.description.librarian |
ej2015 |
en_ZA |
dc.format.extent |
4 pages |
en_ZA |
dc.format.medium |
PDF |
en_ZA |
dc.identifier.citation |
Akella, S & Reddy, KK 2010, 'Energy savings in a hermetic compressor: reducing heat losses', Paper presented to the 7th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics, Turkey, 19-21 July 2010. |
en_ZA |
dc.identifier.uri |
http://hdl.handle.net/2263/44874 |
|
dc.language.iso |
en |
en_ZA |
dc.publisher |
International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics |
en_ZA |
dc.relation.ispartof |
HEFAT 2010 |
en_US |
dc.rights |
University of Pretoria |
en_ZA |
dc.subject |
Hermetic compressor |
en_ZA |
dc.title |
Energy savings in a hermetic compressor : reducing heat losses |
en_ZA |
dc.type |
Presentation |
en_ZA |