Cerebral monitoring during carotid endarterectomy - a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure

Show simple item record

dc.contributor.author Botes, K.
dc.contributor.author Le Roux, D.A.
dc.contributor.author Van Marle, J.
dc.date.accessioned 2007-11-01T13:56:24Z
dc.date.available 2007-11-01T13:56:24Z
dc.date.issued 2007-05
dc.description.abstract OBJECTIVE : Various modalities are used for cerebral monitoring during carotid endarterectomy (CEA). The aim of this study was to evaluate whether transcranial cerebral oximetry (TCO) and carotid stump pressure (SP) are as accurate as electroencephalography (EEG) for monitoring cerebral ischaemia during carotid cross-clamping. METHODS : One hundred consecutive patients who underwent CEA were studied with continuous and simultaneous EEG and TCO. SP was measured for each patient. The percentage decrease of oxygenation on TCO was calculated during cross-clamping and surgery. EEG findings were used as the benchmark to detect cerebral ischaemia and were the indication for insertion of a temporary shunt. The relationship with TCO was observed in terms of percentage decrease in oxygenation. RESULTS : A total of 6 patients were shunted on the basis of their EEG changes. TCO changed more than 20% in these 6 patients, but an additional 12 patients had TCO changes with a normal EEG. This correlated with a decrease in blood pressure (BP) and was corrected by increasing the BP. The positive predictive values (PPVs) and negative predictive values (NPVs) for shunting based on TCO (as compared with EEG) were 33% and 100% respectively. Thirty-four patients had SP < 50 mmHg, of whom 4 were shunted based on EEG changes. Two of 66 patients with SP > 50 mmHg were shunted based on EEG changes. If a shunting policy had been based on a SP of 50 mmHg, 30 patients would have been shunted unnecessarily (PPV 12%), whereas the non-requirement for a shunt was predicted correctly in 64 of 66 patients (NPV 97%). There were 2 major strokes: 1 contralateral on day 3 in a patient with bilateral severe stenoses, and 1 ipsilateral in a non-shunted patient with normal EEG, TCO and SP > 50 mmHg. CONCLUSION : Compared with EEG, TCO is a practical and non-invasive monitoring system with a high sensitivity (100%) but a low specificity. TCO is more sensitive to a drop in BP and responds earlier to these changes than EEG. SP should not be used as the sole predictor for shunting during CEA. en
dc.format.extent 653976 bytes
dc.format.mimetype application/pdf
dc.identifier.citation Botes, K, Le Roux, DA & Van Marle, J 2007, 'Cerebral monitoring during carotid endarterectomy - a comparison between electroencephalography transcranial cerebral oximetry and carotid stump pressure', South African Journal of Surgery, vol. 45, no. 2, pp. 43-46. [http://www.hmpg.co.za/journaldetail.php?journalno=8] en
dc.identifier.issn 0038-2361
dc.identifier.uri http://hdl.handle.net/2263/3843
dc.language.iso en en
dc.publisher Health and Medical Publishing Group en
dc.rights Health and Medical Publishing Group en
dc.subject Carotid endarterectomy en
dc.subject Transcranial cerebral oximetry en
dc.subject.lcsh Cerebral ischemia
dc.subject.lcsh Oximetry
dc.subject.lcsh Electroencephalography
dc.subject.lcsh Brain
dc.subject.lcsh Neural networks (Neurobiology)
dc.subject.lcsh Endarterectomy
dc.subject.lcsh Cerebrospinal fluid shunts
dc.title Cerebral monitoring during carotid endarterectomy - a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure en
dc.type Article en


Files in this item

This item appears in the following Collection(s)

Show simple item record