The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles

Show simple item record

dc.contributor.author Cassel, Nicolette
dc.contributor.author Carstens, Ann
dc.contributor.author Becker, Pieter
dc.date.accessioned 2013-09-23T07:29:32Z
dc.date.available 2013-09-23T07:29:32Z
dc.date.issued 2013-05-07
dc.description.abstract Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT) technique and the test bolus (TB) technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU). For the TB technique, the dogs received a test dose of 15% of 2 mL/kg of 300 mgI/mL iodinated contrast agent, followed by a series of low dose sequential scans. The full dose of the contrast agent was then administered and the scans were conducted at optimal times as identified from time attenuation curves. Mean attenuation in HU was measured in the aorta (Ao) and right caudal pulmonary artery (rCPA). Additional observations included the study duration, milliAmpere (mA), computed tomography dose index volume (CTDI[vol]) and dose length product (DLP). The attenuation in the Ao (BT = 660 52 HU ± 138 49 HU, TB = 469 82 HU ± 199 52 HU, p = 0.13) and in the rCPA (BT = 606 34 HU ± 143 37 HU, TB = 413 72 HU ± 174.99 HU, p = 0.28) did not differ significantly between the two techniques. The BT technique was conducted in a significantly shorter time period than the TB technique (p = 0.03). The mean mA for the BT technique was significantly lower than the TB technique (p = 0.03), as was the mean CTDI(vol) (p = 0.001). The mean DLP did not differ significantly between the two techniques (p = 0.17). No preference was given to either technique when evaluating the Ao or rCPA but the BT technique was shown to be shorter in duration and resulted in less DLP than the TB technique. en
dc.description.librarian am2013 en
dc.description.librarian mn2013
dc.description.uri http://www.jsava.co.za en
dc.identifier.citation Cassel, N., Carstens, A. & Becker, P., 2013, 'The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles', Journal of the South African Veterinary Association 84(1), Art. #930, 9 pages. http://dx.DOI.org/ 10.4102/jsava.v84i1.930 en
dc.identifier.issn 0038-2809 (print)
dc.identifier.issn 2224-9435 (online)
dc.identifier.issn 10.4102/jsava.v84i1.930
dc.identifier.uri http://hdl.handle.net/2263/31785
dc.language.iso en en
dc.publisher OpenJournals Publishing en
dc.rights © 2013. The Authors. Licensee: AOSIS OpenJournals. This work is licensed under the Creative Commons Attribution License. en
dc.subject Beagles en
dc.subject Bolus tracking en
dc.subject Test bolus techniques en
dc.subject Computed tomography thoracic angiography en
dc.subject.lcsh Veterinary tomography en
dc.subject.lcsh Veterinary diagnostic imaging en
dc.title The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles en
dc.type Article en


Files in this item

This item appears in the following Collection(s)

Show simple item record