A framework for HVAC control at a tertiary institution

Show simple item record

dc.contributor.advisor Delport, Johan en
dc.contributor.postgraduate Britz, Eugene Andrew en
dc.date.accessioned 2013-09-07T15:30:17Z
dc.date.available 2005-11-21 en
dc.date.available 2013-09-07T15:30:17Z
dc.date.created 2002-04-01 en
dc.date.issued 2005-11-21 en
dc.date.submitted 2005-11-10 en
dc.description Dissertation (MEng (Electrical Engineering))--University of Pretoria, 2005. en
dc.description.abstract Most utility's and electricity resellers stimulate changes in their load shape through various demand side management activities. The most common way of altering their load shape is through the implementation of different tariff structures. The thesis investigates the effect of combining hot water load control with heating ventilation and air-conditioning load control to reduce the electricity costs due to a demand tariff that is a direct result of demand side management. The entire study is focused on the demand tariff of the University of Pretoria. Although the study was done on the University of Pretoria the methods developed are universal and can be implemented in any situation where hot water load control and heating ventilation and air-conditioning load control are to be combined. The study presents a detailed literature study on the current developments in the field of hot water and heating ventilation and air-conditioning load control. No current work could be found in which the two control methods are combined. Models were developed for controlling the electricity load and for determining the savings. The heating ventilation and air-conditioning load's and the hot water load's uncontrolled load models respectively had a mean absolute percentage errors of 3.83% and 3.2%. The forecasting method used to determine the available energy for pre-cooling and the start time of shedding had a mean absolute error of 3.2%. A case study of the University of Pretoria was done. The effect of using only hot water load control is presented. The case study was expanded to include structural thermal energy storage and then water thermal energy storage. This expansion was done using the HV AC system in combination with the hot water load control system. With an only 10.3% contribution to the university's maximum demand, the hot water load control reduced the university's electricity account (energy + demand) by 5.44%. The heating ventilation and air conditioning load contribute to 6% of the university's maximum demand. With the structural thermal energy storage using the heating ventilation and air conditioning system, the savings increased to 6.12%. With the addition of a 750m3 water thermal energy storage tank to the heating ventilation and air-conditioning system, the savings increased to 7.14%. en
dc.description.availability unrestricted en
dc.description.department Electrical, Electronic and Computer Engineering en
dc.identifier.citation Britz, EA 2001, A framework for HVAC control at a tertiary institution, MEng dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/29370 > en
dc.identifier.other H1218/ag en
dc.identifier.upetdurl http://upetd.up.ac.za/thesis/available/etd-11102005-124321/ en
dc.identifier.uri http://hdl.handle.net/2263/29370
dc.language.iso en
dc.publisher University of Pretoria en_ZA
dc.rights © 2001 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en
dc.subject College buildings heating and ventilation control en
dc.subject UCTD en_US
dc.title A framework for HVAC control at a tertiary institution en
dc.type Dissertation en


Files in this item

This item appears in the following Collection(s)

Show simple item record