Renovation of wastewater for direct re-use in an abattoir

Show simple item record

dc.contributor.advisor Pretorius, W.A. en
dc.contributor.postgraduate Roux, Annalie en
dc.date.accessioned 2013-09-06T16:02:08Z
dc.date.available 2010-04-08 en
dc.date.available 2013-09-06T16:02:08Z
dc.date.created 1997-04-01 en
dc.date.issued 2010-04-08 en
dc.date.submitted 2010-04-08 en
dc.description Dissertation (MSc)--University of Pretoria, 2010. en
dc.description.abstract Tertiary treatment methods were tested on secondary effluent from an abattoir biological wastewater treatment plant with the purpose of renovating it for re-use in the abattoir. The colour and dissolved organic matter could be removed to such an extent that the water would comply with water of insignificant health risk (Department of Health). The treatment process sequence proven to be effective in upgrading this water so insignificant health risk standard were coagulation with a polymer blend, separation, ozonation, filtration and activated carbon filtration. The development of biologically activated carbon in practice was accepted as inevitable and desirable for optimum water quality, but not tested. A deciding factor in the selection of an appropriate treatment was that the final water would also have acceptable corrosion properties. en
dc.description.availability unrestricted en
dc.description.department Chemical Engineering en
dc.identifier.citation Roux, A 1996, Renovation of wastewater for direct re-use in an abattoir, MSc dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/23864 > en
dc.identifier.other H605/ag en
dc.identifier.upetdurl http://upetd.up.ac.za/thesis/available/etd-04082010-095214/ en
dc.identifier.uri http://hdl.handle.net/2263/23864
dc.language.iso en
dc.publisher University of Pretoria en_ZA
dc.rights ©1996, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en
dc.subject Coagulation en
dc.subject Colour en
dc.subject Humic acids en
dc.subject Sedondary effluent en
dc.subject Recycle en
dc.subject Abattoirs en
dc.subject Ozonation en
dc.subject Activated carbon en
dc.subject Biologically activated carbon en
dc.subject UCTD en_US
dc.title Renovation of wastewater for direct re-use in an abattoir en
dc.type Dissertation en


Files in this item

This item appears in the following Collection(s)

Show simple item record