Using distortion product otoacoustic emissions to investigate the efficacy of personal hearing protection

Show simple item record

dc.contributor.advisor Soer, Maggi E. (Magdalena Elizabeth) en
dc.contributor.postgraduate Newland-Nell, Annette Caroline en
dc.date.accessioned 2013-09-06T14:02:34Z
dc.date.available 2004-03-03 en
dc.date.available 2013-09-06T14:02:34Z
dc.date.created 2003-04-09 en
dc.date.issued 2005-03-03 en
dc.date.submitted 2004-03-03 en
dc.description Dissertation (M (Communication Pathology))--University of Pretoria, 2005. en
dc.description.abstract This study aimed to investigate the effectiveness of the Quiet earplug noise protectors worn by a group of South African industrial workers exposed to excessive noise in the workplace. This was achieved by investigating the prevalence and amplitudes of distortion product otoacoustic emissions (DPOAEs), as they have been found to be sensitive to the effects of noise on the cochlea (Vinck, Van Cauwenberge, Leroy,&Corthals, 1999, p. 52). DPOAEs were recorded before and after noise exposure and were compared in order to determine whether the earplugs are providing sufficient protection against cochlear damage. DPOAEs were recorded using a test protocol where the primaries are fixed at L1 = 60dB SPL and L2 = 35dB SPL (L1 - L2 = 25dB) with an f2/f1 ratio of 1.18. The f2 frequencies were selected to correspond closely to the audiometric test frequencies of 2000Hz, 3000Hz, 4000Hz, 6000Hz and 8000Hz. The study found the prevalence of DPOAEs to be statistically stable and repeatable. This was true for DPOAEs measured successively during the same test sitting, as well as comparing prevalence determined before and after exposure to eight hours of noise. DPOAE prevalence alone was therefore not found to be a good indication of the temporary threshold shift (TTS) associated with the effects of noise on the cochlea. However, a significant finding of the study was that normal DPOAEs were recorded in only six right ears (24%) and seven left ears (28%) before noise exposure, even though all the subjects presented with hearing thresholds better than 25dB SPL. This may mean that cochlear pathology is already evident in some of the subjects tested. Further results of the study showed DPOAE amplitudes to be sensitive to the negative effects of excessive noise, as there was a significant difference between DPOAE amplitudes measured before and after the noise exposure. DPOAE amplitudes, specifically in the frequencies that are known to be affected by noise such as 4000Hz and 6000Hz, measured after the work-shift were significantly smaller than those measured before exposure to noise. Although correct usage of the earplugs could not be controlled for the duration of the noise exposure, each subject was instructed on the correct usage of the hearing protection before entering the noise zone. Bearing this limitation of the study in mind, because DPOAE amplitudes were reduced the implication is that the Quiet earplugs are not providing sufficient protection against the harmful effects of noise. en
dc.description.availability Unrestricted en
dc.description.department Speech-Language Pathology and Audiology en
dc.identifier.citation Newland-Nell, A 2003, Using distortion product otoacoustic emissions to investigate the efficacy of personal hearing protection, M dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/22941 > en
dc.identifier.upetdurl http://upetd.up.ac.za/thesis/available/etd-03032004-104906/ en
dc.identifier.uri http://hdl.handle.net/2263/22941
dc.language.iso en
dc.publisher University of Pretoria en_ZA
dc.rights © 2003, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. en
dc.subject Distortion product otoacoustic emissions en
dc.subject Noise-induced hearing loss en
dc.subject Hearing protection en
dc.subject Temporary threshold shift en
dc.subject Permanent threshold shift en
dc.subject Industrial noise en
dc.subject UCTD en_US
dc.title Using distortion product otoacoustic emissions to investigate the efficacy of personal hearing protection en
dc.type Dissertation en


Files in this item

This item appears in the following Collection(s)

Show simple item record