Application of a competitive internal amplification control for the detection of sapoviruses in wastewater

Show simple item record

dc.contributor.author Murray, Tanya Y.
dc.contributor.author Mans, Janet
dc.contributor.author Van Zyl, Walda B.
dc.contributor.author Taylor, Maureen B.
dc.date.accessioned 2013-07-04T11:56:30Z
dc.date.available 2013-07-04T11:56:30Z
dc.date.issued 2013-01
dc.description.abstract In this study, a competitive internal amplification control (IAC) was constructed for application in the real-time reverse transcription-polymerase chain reaction detection of sapoviruses (SaVs). A SaV RNA standard was also created for quantification of the virus. The IAC was included in the screening of environmental samples for SaVs. From August 2010 to December 2011, 51 wastewater samples were collected from five provinces in South Africa. SaVs were found in 72.5 % (37/51) of samples, including four samples where detection was initially inhibited. SaV concentrations ranged from 4.24 × 103 to 1.31 × 106 copies/ml. The IAC successfully identified samples which contained inhibitors and inclusion of an IAC is necessary to ensure the prevalence of SaVs is accurately determined. SaVs are present at high concentrations in wastewater in several provinces of South Africa. This widespread occurrence indicates that SaV circulation in the South African population may be underestimated. en_US
dc.description.librarian hb2013 en_US
dc.description.librarian ay2013 en
dc.description.uri http://link.springer.com/journal/12560 en_US
dc.identifier.citation Murray, TY, Mans, J, Van Zyl, WB & Taylor, MB 2013, 'Application of a competitive internal amplification control for the detection of sapoviruses in wastewater', Food and Environmental Virology, vol. 5, no.1, pp. 61-68. en_US
dc.identifier.issn 1867-0334 (print)
dc.identifier.issn 1867-0342 (online)
dc.identifier.issn 10.1007/s12560-012-9101-1
dc.identifier.uri http://hdl.handle.net/2263/21821
dc.language.iso en en_US
dc.publisher Springer en_US
dc.rights © Springer Science+Business Media New York 2012.The original publication is available at http://link.springer.com/journal/12560 en_US
dc.subject Calicivirus en_US
dc.subject Enteric virus en_US
dc.subject Sapovirus en_US
dc.subject Sewage en_US
dc.subject South Africa en_US
dc.subject.lcsh Sewage -- Microbiology -- South Africa en
dc.title Application of a competitive internal amplification control for the detection of sapoviruses in wastewater en_US
dc.type Postprint Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record