Tracking the degradation of carbon steel mechanical properties due to high-temperature hydrogen attack through strain gauge monitoring

Show simple item record

dc.contributor.author Van Zyl, A.
dc.contributor.author Pretorius, Christiaan C.E.
dc.contributor.author Mathoho, Vhutshilo M.
dc.contributor.author Mostert, R.J. (Roelf)
dc.date.accessioned 2025-03-27T04:47:56Z
dc.date.available 2025-03-27T04:47:56Z
dc.date.issued 2024-11
dc.description.abstract The in-service degradation of the mechanical properties of steel components through the damage mechanism of high temperature hydrogen attack (HTHA), is a topic of concern in the refining and green hydrogen industry. This damage mechanism occurs in susceptible steels operating in environments at high temperatures and hydrogen pressures. The current investigation deals with the indirect monitoring of mechanical degradation via tracking of the swelling strain in affected structures. An autoclave with an AISI 316 shell was utilized to simulate accelerated HTHA damage at 550 °C and 46 bar for exposure times ranging from zero to 700 hours. The progress of the HTHA damage was tracked using encapsulated high-temperature strain gauges. The correlation between the swelling strain and mechanical property degradation was studied to develop a methodology for the continuous monitoring of embrittlement. The tensile sample orientation of the carbon steel plate was included as a variable, i.e., samples parallel, transverse, or perpendicular to the plate rolling direction were included, since it has been shown that the sample orientation influences the HTHA damage features. For the through-thickness orientation, and upon exceeding a threshold value of exposure time, all tensile properties were severely degraded, with values in the order of a 90 per cent reduction being observed. It was found that the degradation of carbon steel mechanical properties can be correlated to the swelling strain measured during exposure. The critical point for mechanical property degradation in the plate through-thickness orientation, whereafter a severe decrease in the ductility of the material occurs, was found to be in the order of 1% of the total swelling strain measured during exposure, equivalent to 65 microstrain. This threshold was found to be significantly lower than that expected from the literature, where limits of 400 to 1000 microstrain were postulated. en_US
dc.description.department Materials Science and Metallurgical Engineering en_US
dc.description.sdg SDG-07:Affordable and clean energy en_US
dc.description.sdg SDG-09: Industry, innovation and infrastructure en_US
dc.description.uri https://journals.co.za/journal/saimm en_US
dc.identifier.citation Van Zyl, A., Pretorius, C.C.E., Mathoho, V.M., and Mostert, R.J. 2024. Tracking the degradation of carbon steel mechanical properties due to high-temperature hydrogen attack through strain gauge monitoring. Journal of the Southern African Institute of Mining and Metallurgy, vol. 124, no.11, pp. 683–692, doi: 10.17159/2411-9717/2486/2024. en_US
dc.identifier.issn 0038-223X (print)
dc.identifier.other 10.17159/2411-9717/2486/2024
dc.identifier.uri http://hdl.handle.net/2263/101743
dc.language.iso en en_US
dc.publisher South African Institute of Mining and Metallurgy en_US
dc.rights © 2024. The Southern African Institute of Mining and Metallurgy. en_US
dc.subject Mechanical properties en_US
dc.subject Strain gauge monitoring en_US
dc.subject Degradation en_US
dc.subject SDG-07: Affordable and clean energy en_US
dc.subject SDG-09: Industry, innovation and infrastructure en_US
dc.subject High temperature hydrogen attack (HTHA) en_US
dc.title Tracking the degradation of carbon steel mechanical properties due to high-temperature hydrogen attack through strain gauge monitoring en_US