Validation of the Lead Care II System in Cape vultures (Gyps coprotheres) in comparison to ICP-MS using pure standards

Show simple item record

dc.contributor.author Naidoo, Vinny
dc.contributor.author Wolter, Kerri
dc.date.accessioned 2025-01-17T06:23:51Z
dc.date.available 2025-01-17T06:23:51Z
dc.date.issued 2024-09
dc.description DATA AVAILABITY STATEMENT: The data is available in the publication. en_US
dc.description.abstract Lead toxicosis remains a concern in raptors, especially following feeding on carcasses sourced from hunting. Rapid diagnosis of lead exposure and easy field monitoring is desirable. The LeadCareII analytical system, validated for rapid diagnoses of lead toxicity in humans, has been described as a useful evaluation system in various species. For this study we attempt to validate the LeadCareII system in the Cape Vulture (CV) (Gyps coprotheres). Blood samples from CV housed under captive conditions and low background lead exposure, were pooled and spiked with known concentrations of a lead standard (0–60 µg/dL). Samples were analyzed by the LeadCareII system and by ICP-MS. The final results showed that despite good linearity the LeadCareII system underestimated lead concentrations by up to 50 %. While the results can be corrected by the derived equation, this is not supported due to the large underestimations evident. The reason for the underestimation is presently unknown. en_US
dc.description.department Paraclinical Sciences en_US
dc.description.sdg SDG-12:Responsible consumption and production en_US
dc.description.sdg SDG-15:Life on land en_US
dc.description.sponsorship VulPro and the National Research Foundation of South Africa. en_US
dc.description.uri https://www.elsevier.com/locate/etap en_US
dc.identifier.citation Naidoo, V. & Wolter, K. 2024, ‘Validation of the lead care II system in cape vultures (Gyps coprotheres) in comparison to ICP-MS using pure standards’, Environmental Toxicology and Pharmacology, vol. 110, art. 104530, pp. 1-5, doi : 10.1016/j.etap.2024.104530. en_US
dc.identifier.issn 1382-6689 (print)
dc.identifier.issn 1872-7077 (online)
dc.identifier.other 10.1016/j.etap.2024.104530
dc.identifier.uri http://hdl.handle.net/2263/100122
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.rights © 2024 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/). en_US
dc.subject Lead en_US
dc.subject LeadCare en_US
dc.subject Validation en_US
dc.subject Accuracy en_US
dc.subject Precision en_US
dc.subject SDG-12: Responsible consumption and production en_US
dc.subject SDG-15: Life on land en_US
dc.subject Cape vulture (Gyps coprotheres) en_US
dc.subject Inductively coupled plasma mass spectrometry (ICP-MS) en_US
dc.title Validation of the Lead Care II System in Cape vultures (Gyps coprotheres) in comparison to ICP-MS using pure standards en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record